Returning Customer, Please Sign In.



You Have Hidden Items

Left Boxes

Click On Hidden Item To Restore

Center Boxes

Right Boxes


Thomas BM175-10PT Programmable Sequential Blasting Machine Pack

Programmable Sequential Blasting MachinesBM175-10PT and BM225-10PT

BM175-10STGeneral Information

    The REO ST and PT series Sequential Blasting Machines are modern easy-to-use programmable timing machines meeting the special requirements of bench blasting operations while precise millisecond/microsecond accuracy is critical.
    Programmable timing permits the blaster to take full advantage of the greater accuracies offered bt the new electronic detonators to achieve better fragmentation and to control ground vibration.  The REO Sequential Blasting Machines allow the blaster to continue full production blasting which otherwise would be drastically curtailed if a single circuit machine were employed.
    The REO Sequential Blasting Machines are of solid-state capacitor-discharge design with 10 circuits that fire one after the other sequentially at preselected time intervals from 1 to 999 milliseconds in 1 millisecond increments.  For special requirements, timing selection increments of 100 microseconds to 10 milliseconds are offered.
    The BM175 and BM225 series Blasting Machines are 450 volt output models and are recommended for most applications.  These models have a cable receptacle on the top panel and require an EC15 series Extension Cable and TB15 Terminal Board to connect to the detonator lead lines.
    The timing interval between circuits on the BM175-10ST Blasting Machine is selected and set on a single switch, and the selected timing is Identical between each circuit.
    The timing intervals between circuits on the -10PT series Blasting Machines are selected and set independently on each of nine switches (ten switches on slave models), and the selected timing may be Different between each circuit.
    The -10PT series Blasting Machine is available in Master and Slave models for applications that require more than 10 circuits.  Up to fifteen ten-circuit Slave units can be added as needed.
    The BM175 and BM225 series Blasting Machines are available in two Remote models.  The -10PT-RC series operates from the battery powered RC70 Remote Control.  The -10PT-RM series operates from mains power.
    Several models that bypass open circuits (BOC) are offered for BOCAR (Bypass Open Circuit Automatic Redundancy) blasting methods.  All models are available with a Key feature.
    The -10PT series Blasting Machine is available with a Trigger Output that provides and optically isolated output when circuit 1 fires.

Explanation of Model Numbers

Explanation of Model Numbers

Characteristics

Model
No. of Timing Switches
No. of Blasting Circuits
Individual Circuit Rating
Circuit Capacity²
Weight
(Shipping Weight)
Size
Power Source
(Alkaline Batteries)
Volts
Energy
BM175-10ST
1
10¹
450
9 Joules
80 detonators
175 ohms/
Circuit
Single
Series
circuit only
20.2 lbs. (9.2 kg.)
[23 lbs. (11 kgl)]
6.8 x 12.5 x 11.8 in.
(17.3 x 31.7 x 30.0 cm)
Ten 1.5 volt "D" Cells Eveready E95 or equal
BM175-10PT 9
BM175-10PT-M 9
BM175-10PT-S 10
BM175-10PT-RC 9
BM175-10PT-RM 9
200/250 volts
50/60 Hz. Mains
BM225-10PT 9
15 Joules
105
detonators
225 ohms/
circuit
Single
Series
circuit only
Ten 1.5 volt "D" Cells
Eveready E95 or equal
BM225-10PT-M 9
BM225-10PT-S 10
BM225-10PT-RC 9
BM225-10PT-RM 9
200/250 volts
50/60 Hz. Mains
BM225-10PT-BOC 9
Ten 1.5 volt "D" Cells
Eveready E95 or equal
BM225-10PT-M-BOC 9
BM225-10PT-S-BOC 10
RC70
-
-
-
-
-
8 lbs. (3.6 kg.)
[11 lbs. (5 kg.)]
6.4 x 10.5 x 4.8 in
(16.3 x 26.6 x 12.1 cm.)
Twelve 1.5 volt "D" Cells
Eveready E95 or equal

¹ - A receptacle is provided to accomodate an extension cable and TB15 Terminal Board.
² - 12 ohm maximum lead line and 2 ohm EB detonators wired in a single series circuit, based on US standard detonator rating of 20 millijoules/ohm delivered in 5 milliseconds.  Contact your power company for recommendations.

Features

  • Permits initiating larger blasts while meeting stringent blasting regulations.
  • Helps control vibration and noise.
  • Improves fragmentation through accurate or improved delay blasting.
  • Choice of any MS interval from 1 MS to 999 MS in 1 MS increments.  Microsecond timing is available on special order.
  • Remote models available.
  • Master permits adding 10-circuit slave units as necessary.
  • Reliable.  Blasting machine will not fire or discharge until fully charged to design voltage.
  • Safety interlock.  "Charge" and "Fire" switches must both be depressed for the blasting machine to fire.  Blasting machine is rendered inactive when switches are released.
  • Sturdy construction for extended life.
  • Rugged water and corrosion resistant stainless steel case.
  • Environmentally sealed to operate in most weather.
  • Solid state circuitry assures excellent reliability and service life.
  • Heavy-duty, long life Alkaline batteries provide efficient and dependable power.
  • Fast battery change using readily available standard Alkaline batteries.  No special tools are required.
  • Temperature compensated circuits facilitate cold weather operation.
Operation

    Use of this equipment requires training in sequential blasting techniques.  Contact your powder company representative for training information.  This equipment must be operated in accordance with US Federal health and safety standards, state laws, rules, and other applicable statutory provisions.
Suitability:  Properly trained and skilled personnel must determine suitability and safety factors of each blast.
Important:  Devices such as the REO Blasting Machine Energy Testers must be used to determine the energy output of each circuit prior to each blast.  The extension cable shall not be connected to the blasting machine until the circuit wiring has been verified by approved testers, the blast is ready to be fired, and area safety is assured.
    After the blasting circuits have been connected to the blasting machine, depress the Charge switch and hold it down.  When the Ready to Fire indicator lights, depress the Fire switch while continuing to depress the Charge switch.  Unless the Charge and Fire switches are operated together, the machine will not fire.  The Cap Circuit indicators, when lit, indicate the probability that circuit fired.  The machine will stop firing at an open circuit, except -BOC series Blasting Machines which continue sequencing even if a circuit is open.
Caution:  With this machine, as with all blasting equipment, standard safety rules should be followed which include: keep blast area clear of unauthorized personnel, keep body and hands away from conductors and use only approved test equipment.

Master-Slave Configuration

    The -10PT series Blasting Machines are available as a master or slave.  Up to fifteen slaves may be connected to the master to provide up to 160 detonator circuits (10 on the master and 10 on each slave) as required.  The slave(s) receive the charge and fire signals from the master.  The programmable timing between circuits is selected on the master and slave(s) as needed.

Remote Configuration

    Four remote models are available.  The BM175-10PT-RC and BM225-10PT-RC operate up to 2000 feet from the RC70 battery operated remote control using 20 gauge or heavier duplex wire.  The BM175-10PT-RM and BM225-10PT-RM operate from 200/250 volts, 50/60 Hz mains power.

Battery Life
   
    A lighted Ready to Fire indicator confirms that the battery power was sufficient to charge the capacitors to the design voltage and the safety circuit is released.
    The amount of time it takes for the Ready to Fire indicator light to illuminate reflects remaining battery life.  After months of use, a longer charge time will be required.  However, regardless of battery condition, the full design voltage is present and the unit's safety circuit is released if the Ready to Fire indicator is illuminated. 

BM175-10 series   up to 450 charges
BM225-10 series   up to 250 charges

Safety Features
  1. Blasting machine cannot be fired until the design voltage is verified and the safety circuit is released.
  2. Case is sealed against moisture and dust.
  3. Padlock latch on a hinged cover provides a means to increase security protection.
  4. Capacitors are shunted until the "Charge" switch is depressed.
  5. Blasting circuits are shunted until the "Fire" switch is depressed.
  6. Cable receptacle is protected by the cover.
  7. No exposed terminals.



OhmmeterBlaster's Ohmmeters

General InformationOhmmeter

The REO Blaster's Ohmmeters provide nominal values of circuit resistance on a large easy-to-read digital display.  The user-friendly ohmmeters speed up circuit check-out and provide vital information necessary to assure a successful blast.  Long battery life, rugged water resistant enclosures and heavy duty terminals provide the blaster with a dependable ohmmeter that provides years of service.  The B0199.9-10 (0 - 199.9 ohms) and the B01999-1 (0 - 1999 ohms) Blaster's Ohmmeters are pocket-sized single circuit models designed for general use.  A nylon cord attatched to the case allows the ohmmeter to hang from around the neck for convenient use.  The B0199.9-10 (0 - 199.9 ohms) and the B01999-10 (0 - 1999 ohms) Blaster's Ohmmeters are ten circuit models designed for REO Sequential Blasting Systems and include a special set of terminals for single circuit testing.  The sequential blasting cable is connected to a socket on the ohmmeter thus allowing rapid resistance measurement of each circuit selected by a rotary switch.

Characteristics

Model
Number of Circuits
Range
Accuracy
Maximum Test Current
Weight (Shipping Weight)
Size
Power Source (Alkaline Batteries)
B0199.9-1
1
0 - 199.9 ohms
±0.1 ohm
2.7 milliamperes
8 oz.  (0.2 kg.)
[2 lbs. (1 kg.)]
4.1 x 1.3 x 3.6 in.
(10.5 x 3.4 x 9.0 cm.)
One 9 Volt Eveready 522 or equal
B01999-1
0 - 1999 ohms ±1 ohm
1.2 milliamperes
B0199.9-10
10+ Single
0 - 199.9 ohms ±0.1 ohm
2.7 milliamperes
2.5 lbs.  (1.1 kg.)
[4 lbs. (2 kg.)]
9.0 x 8.0 x 3.4 in.
(22.9 x 20.3 x 8.6 cm.)
B01999-10
0 - 1999 ohms ±1 ohm
1.2 milliamperes


Features
  • Digital read-out to 199.9 ohms in 0.1 increments (B0199.9-1 and B0199.9-10) or 0 to 1999 ohms in 1 ohm increments  (B01999-1 and B01999-10).
  • Automatic turn-on and shut-off.
  • Low battery indication.
  • Laborsaving fast connections for quick hole-to-hole or circuit analysis.
  • Rugged water and corrosion resistant nylon  (B0199.9-1 and B01999-1) or ABS  (B0199.9-10 and B01999-10) plastic case.
  • Environmentally sealed to operate in most weather.
  • Safety yellow is easy to spot by equipment operators.
  • Easy-to-follow instructions provided on the unit.
  • Fast battery change using readily available standard Alkaline battery.
  • Heavy duty bare terminals accept wires, banana plugs, clips or spade terminals.

Operation

    When using the REO B01999-1 or B01999-1 Blaster's Ohmmeter, connect the blasting circuit to the terminals.  The ohmmeter turns on automatically.  The display indicates the resistance of the blasting circuit.  "1"  will be displayed is the resistance exceeds the full scale range of the ohmmeter.  The ohmmeter turns off automatically when disconnected.  Replace the battery when BAT appears on the display.
   
    When using the REO B0199.9-10 or B01999-10 Blaster's Ohmmeter, connect the sequential blasting cable to the Cable connector.  The ohmmeter turns on automatically.  Rotate the circuit switch to positions 1 through 10, noting the resistance displayed for each circuit.  "1" will be displayed if the resistance exceeds the full scale range of the ohmmeter.  To measure the resistance of a single circuit, connect the blasting circuit to the Single Circuit terminals and rotate the Circuit switch to the Single position, noting the resistance displayed.  The ohmmeter turns off automatically when disconnected.  Replace the battery when BAT appears on the display.

Battery Life

Low battery drain provides battery life of more than 2000 hours of tester operation.



TB15 Terminal BoardTerminal Board

    The TB15 Terminal Board is a compact, durable, rugged, lightweight printed circuit design with 10 pairs of hookup terminals for up to 10 circuits.  A socket is provided for connecting extension cables.  The AD Load Plug provides the shunting requirement during connection of the detonators to the terminal board.  In addition, the terminal board provides convenient Load Plug storage.  Shipping Weight:  5 lbs. (2.3 kg.)





BMS10 Blaster's Multimeter Switch
Multimeter Switch

    The BMS10 Blaster's Multimeter Switch is used with an REO B0199.9-1 or B01999-1 Single Circuit Blaster's Ohmmeter or other single circuit Blaster's Multimeters or Blasting Glavanometers when an REO B0199.9-10 or B01999-10 Ten Circuit Blaster's Ohmmeter is not available.  The BMS10 aids in checking for errors and broken wires in multiple blast circuits.  A blasting cable receptacle with an attatched screw-on duct cap and two meter terminals provide the necessary connection between the meter and the blasting circuits.  The enclosure is a rugged water and corrosion resistant polycarbonate plastic case.  Shipping Weight:  2 lbs.  (0.9 kg.)



Blasting Machine EC15-2, EC15-10, EC15-250, EC15-300, and EC15-500 Extension Cables
Blaster Extension Cable

    Blating Machine cables are available in 2 ft. (0.6m), 10 ft. (3.0m), 250 ft. (76.2m), 300 ft. (91.4m), and 500 ft. (152.4m) lengths.  The EC15-10, EC15-250, EC15-300, and EC15-500 cables are used to connect the blasting machine to the TB12 or TB15 terminal board.  The EC15-2 cable is used to connect the energy tester to the blasting machine.  Cables of other lengths are available upon request. 

Shipping Weight
EC15-2
1 lb.
(0.5 kg.)
EC15-10 1 lb.
(0.5 kg.)
EC15-250 17 lbs.
(7.7 kg.)
EC15-300 21 lbs.
(9.5 kg.)
EC15-500 32 lbs.
(14.5 kg.)




AD5 and AD6 Load Plugs
Load Plugs

    The AD5 (BM175 series) and AD6 (BM225 series) Load Plugs are used to test blasting machines.  The load plug contains 10 resistors, each equal to the maximum load resistance of the blasting machine.  Shipping Weight:  1 lb. (0.5 kg.)

Add to Cart:

  • Model: BM175-10PT
  • Manufactured by: Thomas

This product was added to our catalog on Tuesday 24 August, 2010.